Choosing the same door or duty class for every passage confuses the entrance queue with internal forklift traffic. This guide creates separate decisions for vehicle entry, internal passages, despatch doors and loading points. The dealer and facility/project teams provide traffic and building data; Alkur does not conduct site surveys, installation or on-site service.
Define the flow before selecting products
- Identify each passage. Give every entrance, internal corridor, despatch door and dock its own reference. Show pedestrian and vehicle routes on the same layout.
- Record peak periods. Include vehicle type, daily totals, peak-hour crossings, movement time and queues. A shift average alone does not select motor or barrier capacity.
- Match load and environment. Assign forklift self-weight plus cargo, vehicle bed height, temperatures on both sides and required separation to each point.
- Check building dependencies. The project team assesses openings, overhead services, vehicle turns, platform/lip contact, pit drawings and cabling. Confirm the relevant drawing before concrete or asphalt.
- Select motor and control scope. Match mechanics, motor, controller/limits, safety and access together; detecting vehicle presence does not authorise passage.
- Assign decision owners. The facility confirms usage, project parties building/electrical design, and the dealer product/installation scope. Close missing inputs before finalising the order configuration.
Match information and guides to the point
| Point | Traffic and vehicle | Load and environment | Building/control dependency | Related guide |
|---|---|---|---|---|
| Vehicle entry | Heavy vehicles, peak queues, turning | Vehicle profile and outdoor conditions | Clear passage, barrier housing/support, weighbridge/access permission | Barrier selection |
| Internal passage | Forklifts/pedestrians, both directions, waiting | Carried load, temperature and zone separation | Opening, activation, safety, open time | Cold chain / Food hygiene |
| Despatch door | Peak cycles and actual movement time | Door configuration and outdoor conditions | Lift type, motor-controller-limits, maintenance access | Motor selection |
| Loading point | Vehicle type and docking at each bay | Forklift + cargo, vehicle/dock levels | Platform, lip contact, pit and shelter | NORMDOCK selection |
Keep dock distinctions intact
NORMDOCK’s 6 000 kg dynamic / 9 000 kg static figures are not alternative moving-load ratings. Record forklift plus cargo and verify crossing suitability against conditions. The 2 000 × 2 500 mm and 2 000 × 3 000 mm platform names alone do not establish forklift manoeuvring space or vehicle suitability. Their separate pit drawings show 80 × 80 mm angle and 50 mm conduit with their own dimensions.
Recommended +32 / −32 cm refers to ramp travel, not pit depth. A 600 mm standard/1 000 mm optional telescopic lip is not a vehicle-to-building gap. The hinged brochure’s single/three-flap (1+2) option does not establish telescopic movement or speed.
Assess door duty and vehicle entry separately
NORMTOR lists 15 000 standard and 25 000/50 000/100 000 optional spring cycles. These are not installed-door years or motor duty limits. The GYK-92SY document’s GYM100S-2 label “S2 20% (10 minutes continuous operation)” does not establish two minutes of movement/four cycles for every door; movement time, load and thermal conditions need separate confirmation.
The roll-up HPVC specification lists 0.65–0.70 m/s without an inverter and up to 1.5 m/s with one; the folding type lists up to 1.5 m/s with an inverter. These speeds do not produce the same waiting or energy result at every opening; assess open time and safe passage together.
For FRIG 4000–5000/6000–7000 and TROYA 4000–5000/6000–7000, use current model documents, not old DINAMIX timings. Design loop cabling and detection area against the selected detector manual. Keep detection separate from weighbridge/card/plate access permission.
Output: a passage decision schedule
For each point, record identity, traffic profile, load/height/temperature data, product-motor-controller choice, drawing/document identity, infrastructure responsibility and open confirmations. The dealer and project parties track decisions in one schedule. A missing dimension at one door or drawing at one dock then remains a specific open issue rather than a facility-wide assumption. Transfer confirmed configurations to ordering and handover records.
Sources and evidence
Original sources for this publication and the specific information each link supports.
- NORMDOCK hinged dock leveller technical specification, REV03 (opens in a new tab) PDF language: TR / EN
- Publisher:
- Alkur Kapı Sistemleri
- URL
- alkur.com.tr
- Published:
- Last verified:
Claim supported: REV03, PDF pp.2–3: hinged ramp; EN p.3 distinguishes 6000 kg dynamic/9000 kg static loads, recommended ±32 cm travel and EN 1398 requirements. Specification scope only, not an independent compliance test or every-site guarantee.
- NORMDOCK telescopic dock leveller specification (opens in a new tab) PDF language: TR / EN
- Publisher:
- Alkur Kapı Sistemleri
- URL
- alkur.com.tr
- Published:
- Last verified:
Claim supported: REV03, PDF pp.2–3: telescopic lip 600 mm standard/1000 mm optional; EN p.3 lists 6000 kg dynamic/9000 kg static loads and recommended ±32 cm travel. Lip length is not a safe truck gap; pit and bed contact need project verification.
- NORMDOCK 2000 × 2500 leveller pit detail (opens in a new tab) PDF language: TR / EN
- Publisher:
- Alkur Kapı Sistemleri
- URL
- alkur.com.tr
- Last verified:
Claim supported: PDF p.2: pit drawing for the 2000 × 2500 mm platform only, 80 × 80 mm angle and 50 mm cable conduit. Platform dimensions are not pit dimensions and must not be transferred to another platform drawing.
- NORMDOCK 2000 × 3000 leveller pit detail (opens in a new tab) PDF language: TR / EN
- Publisher:
- Alkur Kapı Sistemleri
- URL
- alkur.com.tr
- Last verified:
Claim supported: PDF p.2: pit drawing for the 2000 × 3000 mm platform only, 80 × 80 mm angle and 50 mm cable conduit. Platform dimensions are not pit dimensions and must not be transferred to another platform drawing.
- NORMDOCK loading systems brochure (opens in a new tab) PDF language: TR / EN
- Publisher:
- Alkur Kapı Sistemleri
- URL
- alkur.com.tr
- Last verified:
Claim supported: PDF p.2 EN technical features: hinged type has single-flap or three-flap (1+2) options. This brochure does not establish movement speed or a telescopic lip; use the selected platform’s separate pit drawing.
- NORMTOR Industrial Sectional Door Technical Specification (opens in a new tab) PDF language: TR / EN
- Publisher:
- Alkur Kapı Sistemleri
- URL
- alkur.com.tr
- Published:
- Last verified:
Claim supported: TR REV05, PDF pp.2–3: 40 mm/40 kg/m³/0.40 mm sandwich panel, RAL 9002, lift arrangements and 15,000 standard/25,000–100,000 optional spring cycles. Panel values are not whole-door performance; cycles are not a year-based warranty.
- GYK-92SY Control Unit Installation and User Manual (opens in a new tab) PDF language: TR
- Publisher:
- Alkur Kapı Sistemleri
- URL
- alkur.com.tr
- Last verified:
Claim supported: PDF p.2, GYM100S-2 table: “S2 20% (10 minutes continuous operation)” label. It does not establish two minutes of motion/four cycles for every door; motor load and thermal limits need separate verification.
- ALKUR roll-up HPVC door specification (opens in a new tab) PDF language: TR / EN
- Publisher:
- Alkur Kapı Sistemleri
- URL
- alkur.com.tr
- Published:
- Last verified:
Claim supported: TR REV02, PDF p.2 §4-5: roll-up HPVC speed up to 1.5 m/s with inverter, 0.65–0.70 m/s without. Depends on selected motor/installation; not a fixed speed for folding doors or every HPVC configuration.
- Folding HPVC technical specification, Turkish REV03 page (opens in a new tab) PDF language: TR / EN
- Publisher:
- Alkur Kapı Sistemleri
- URL
- alkur.com.tr
- Published:
- Last verified:
Claim supported: TR REV03, PDF p.2 §4-4: folding HPVC up to 1.5 m/s with inverter. Limited to this model/configuration; not a fixed speed, energy-saving percentage or motor/controller compatibility guarantee.
- r-tec loop detector manual (opens in a new tab) PDF language: TR
- Publisher:
- Alkur Kapı Sistemleri
- URL
- alkur.com.tr
- Last verified:
Claim supported: PDF p.1: this single-channel loop uses a 3 cm wide/5 cm deep channel, five turns and frequency selection. Not a universal installation recipe for every detector or site surface.
Questions on this topic