Planning Access Control at Car Parks and Residential Entrances
Published:
Publisher: Alkur Kapı Sistemleri A.Ş.
By: Ercan Erdoğan
Entrance planning starts with who uses each lane and how vehicle detection combines with access permission. The output is an entrance-plan record bringing together dealer-supplied passage data, control sequence and outage expectations.
Decision sequence for access control
- Record entry/exit lanes, vehicle types and a separate pedestrian route. Distinguish physical closure from traffic regulation.
- Choose a barrier, sliding gate or both. Add clear passage after cabinet, support and manoeuvring allowances to the dealer-supplied drawing.
- Assess the full permission–opening–vehicle passage–waiting–closing cycle at peak time.
- Identify which device detects presence, which grants permission and which command reaches the controller.
- Define lost transmitter/card, visitor and outage scenarios. Mark deletion methods affecting all records separately.
- The dealer’s technical team records detection, safety, closing sequence and manual-operation results on the installation.
Barrier or sliding gate?
The two products do different jobs, and on most projects the choice follows the security requirement.
A barrier regulates vehicle passage but does not fully close the opening to pedestrians or cyclists. Its opening time and duty limits are checked for the exact model and arm; the traffic profile, visitor control and any weighbridge sequence determine suitability.
A sliding gate closes the opening and can provide a physical boundary outside working hours. Its passage time depends on opening width, model speed, acceleration and control settings; no single time applies to all sliding gates.
At many sites both are used: the barrier manages flow by day, the gate closes the site at night.
Boom length and installation position
Boom length is not clear passage. Draw cabinet, support, resting position and vehicle movement together. Use the selected current FRIG or TROYA model’s document for dimensions and times; old DINAMIX or WM values do not transfer to a new sales name.
Agree foundation, structure and cable routes before concrete work. A need for wall mounting does not establish that the current range offers it; assess that condition with the partner.
Passage time includes permission checks, opening, vehicle travel, dwell and closing. Assess peak queues using the full sequence.
Detection and authorisation
Access control has two distinct layers that should not be confused: detection says a vehicle is there, authorisation says it has the right to pass.
A loop detector senses vehicle presence. The UltraII sheet’s 3 cm × 5 cm channel, five turns and box 25 cm from the controller are that document’s installation example. Dimensions, turns and position do not apply to all detectors; use the installed model’s manual and the dealer team’s application data.
Card reader is selected by the required authorisation method and verified interface. The local site does not provide an exact reader datasheet establishing frequency, memory capacity or enclosure rating; these values are confirmed for the ordered model.
Remote control must match the receiver’s protocol and programming rules. The G24 manual describes RF433 options and company-code restrictions; it does not establish one memory capacity or compatibility promise for all receivers.
Plate recognition removes the need to carry a card or remote; resident and visitor separation is managed on the software side.
Verify revocation against the installed system when a card or transmitter is lost. RF433 FIX and ROLLING manuals describe erasing all transmitters, not one lost record. Delete-all or ROLLING mode changes affect other users too; prepare re-pairing. Individual card revocation needs the selected reader/software’s documented procedure.
Adjacent entry and exit lanes
Assess interference between neighbouring loops through layout and detector settings. The chosen detector’s manual defines frequency options. Channel size, turns and box position are not a universal recipe. A competent team verifies detection and the control sequence with actual vehicles at commissioning.
What happens during an outage?
If the entrance must keep working during a power cut, plan a backup supply and manual release from the start. A battery option is not identical across motors and controllers; confirm compatibility and wiring in the selected model’s manual. Runtime or cycle count during an outage depends on the battery and installed system and should be tested on site before a figure is promised.
Electric vehicle charging on the same project
If EV charging is included, assess total load and panel protection separately. WCU-22 documents 400 V three phase/32 A and up to 22 kW, no built-in RCD and external 30 mA protection at the panel. Load management must be verified for the ordered configuration.
Entrance plan and handover record
| Scenario | Planned behaviour | Result to record |
|---|---|---|
| Authorised vehicle | Permission → detection → allowed movement | Reader/receiver, input and control sequence |
| Vehicle detected, no permission | Detection alone grants no access | Control logic preserves the distinction |
| Lost transmitter | Revocation method supported by the model | Individual/all deletion, affected users, re-pairing |
| Outage | Verified manual/battery method | Installed equipment and tested behaviour |
| Adjacent lane | Loop inputs should not interfere | Detector/settings and vehicle-test result |
The output contains the lane drawing, device/interfaces, permission/detection sequence, deletion scope and outage behaviour. The dealer submits unresolved model pairings for manufacturer assessment. Alkur does not survey sites or install the entrance.
For movement, photocell, limit or transmitter symptoms, use the model-specific checks in r-tec Error Codes and Fault Symptoms.
Sources and evidence
Original sources for this publication and the specific information each link supports.
- GATE 24 control unit manual (opens in a new tab) PDF language: TR
- Publisher:
- Alkur Kapı Sistemleri
- URL
- alkur.com.tr
- Last verified:
Claim supported: Pages 2–5 define G24 application classes and controls; pages 10–12 describe RF433 receiver options and company-code/programming restrictions. Neither application class nor 433 MHz frequency alone establishes universal replacement compatibility.
- r-tec UltraII (TR) (opens in a new tab) PDF language: TR
- Publisher:
- r-tec
- URL
- alkur.com.tr
- Last verified:
Claim supported: PDF p.1: UltraII channel/turns/box example, frequency and contacts. 3 cm × 5 cm, five turns and 25 cm belong to this model example, not a universal recipe.
- r-tec RF433 FIX (TR) (opens in a new tab) PDF language: TR
- Publisher:
- r-tec
- URL
- alkur.com.tr
- Last verified:
Claim supported: PDF p.2: pairing and erasing all records. Individual-record deletion is not described.
- r-tec RF433 ROLLING (TR) (opens in a new tab) PDF language: TR
- Publisher:
- r-tec
- URL
- alkur.com.tr
- Last verified:
Claim supported: PDF pp.2–3: company code, standard/common mode and delete all. Changing mode erases records; deletion retains company binding.
- r-tec WCU-22 (TR) (opens in a new tab) PDF language: TR
- Publisher:
- r-tec
- URL
- alkur.com.tr
- Last verified:
Claim supported: PDF pp.6 and 8: 400 V three phase/32 A, up to 22 kW; no built-in RCD, external panel protection 30 mA. Management is not assumed for every configuration.
Record templates you can use
Templates are completed by the dealer and technical team; checks follow the device’s own manual.
Commissioning and handover record
Completed by the dealer and trained technicians. Record only checks in the installed model's manual and identify functions that do not apply. This record is not a declaration of conformity.
Show the blank record table
| Record field | Record / result |
|---|---|
| Date / record reference | |
| Dealer / technical team | |
| Door model / installation reference | |
| Motor model / revision | |
| Control-board model / revision | |
| Receiver model / revision | |
| Lift / installation drawing and revision | |
| Manual used / revision / page | |
| Supply / protection arrangement (technician record) | |
| Planned use / intensity | |
| Installed safety and access equipment |
| Function checked | Manual / procedure | Observed result / open finding |
|---|---|---|
| Mechanical movement / balance | ||
| Opening and closing limits | ||
| Installed safety functions | ||
| Commands / remote and receiver | ||
| Manual use / power-loss behavior | ||
| User instruction |
| Record field | Record / result |
|---|---|
| Resolved findings / open points | |
| Manuals and documents handed over | |
| Handed over by / received by / date |
Questions on this topic
You can open the related FAQ question for a short answer.