Technical files
Documents
Specifications and installation information can be viewed or downloaded as PDFs from our server.
Technical specifications
1Key technical specifications
The most critical technical parameters of this product.
- Mains voltage (with FU)220VAC single-phase
- Mains voltage (with I-380)3 × 380VAC three-phase
- Motor torque class85Nm
- Opening speed2.0m/s
- Target door size4 × 4m (max. HPVC)
- Drive typeØ140 aluminium drum (integrated)
Show all technical specifications (10)
Mechanical
| Feature | Value |
|---|---|
| Protection class | IP54 |
Control
| Feature | Value |
|---|---|
| Compatible control board (220 V) | FU (mandatory inverter) |
| Compatible control board (380 V) | I-380 |
Performance
| Feature | Value |
|---|---|
| Soft start / stop | Standard (PVC protection) |
Overview
The standard driver behind the ALKUR HPVC fast PVC door is the r-tec RAPID 85. With its 85 Nm torque class, 2.0 m/s high opening speed and integrated Ø140 aluminium drum, it takes on the role of key drive motor for cold chain, food production, pharmaceutical facilities and industrial lines that demand fast passage. Depending on the site’s infrastructure, it runs with either an FU (220 V) or an I-380 (380 V) control board.

HPVC + RAPID 85 — system logic
HPVC door wraps PVC fabric vertically onto a drum — soft fabric is used instead of conventional sectional door panels. This architecture means:
- High speed — 2.0 m/s = ~5 times that of standard sectional (0.4 m/s)
- Interior climate protection — Fast passage = minimum cold air escape
- Drum wrapping — Fabric is wrapped 3-4 turns on Ø140 aluminium drum
- Soft start mandatory — Hard start wears the fabric
RAPID 85 is specifically designed for this architecture; installing conventional sectional motors on HPVC shortens fabric + drum life.
FU vs I-380 — control selection
| Facility supply | Recommended control | Description |
|---|---|---|
| 220 V single-phase | FU | Generates 3-phase inverter from single-phase (2 200 VA) |
| 3 × 380 V three-phase | I-380 | Direct 3-phase drive, 10% energy efficiency |
| 3 × 230 V three-phase (old facility) | FU | I-380 requires 380 V |
→ New facilities are mostly 380 V three-phase → I-380 primary. Existing residential/small facilities 220 V single-phase → FU mandatory.
Speed importance — cold-chain example
In an HPVC door between cold storage (-25 °C) and shipping area, every second of interior climate escape = energy cost:
- Standard sectional door (0.4 m/s): 3 m height = 7.5 sec open
- HPVC + RAPID 85 (2.0 m/s): 3 m = 1.5 sec open
- Forklift passage frequency 100/day → 600 sec/day vs 150 sec open difference
- Annual energy saving: ~30% cooling load
→ RAPID 85’s 2.0 m/s speed is not just operational speed but direct energy + interior environment control gain.
Target projects
- Cold storage HPVC door (food, pharma, logistics)
- Production line partition door (automotive, white goods)
- Food facility clean area / dirty area separation (hygiene + speed)
- Pharmaceutical sector GMP clean room door
- Fast-passage loading ramp front
- Automotive sub-supplier narrow passage
Field discipline
- Soft start calibration — Ramp duration is set to 1.5-2 sec via FU/I-380 trimpot; harder ramp wears the PVC fabric
- Drum wrap tension — Periodically check fabric tension on Ø140 drum; loose wrap causes fabric crease during opening
- PVC fabric quality — 900 gr/m² standard; reinforced 1100 gr/m² for heavy work or cold chain
- Thermal protection — Motor thermal value monitored on high-frequency open-close (30+ cycles/hour)
- Limit switch — RAPID 85 uses standard limit switch for position control
- Periodic maintenance — Once every 3 months drum wrap + fabric tension + reducer oil check
Contact our team for model-specific information or a quote.