- Full product name SIRIUS 10024 TCE
- Power supply 380 V three-phase
- Motor power 0.37 kW
- Torque 100 Nm
- Movement speed 24 cm/sec
- Limit switch Electronic limit switch
Show all technical specifications (10)
Mechanical
| Feature | Value |
|---|---|
| Drive | Shaft driven |
| Manual mode | Chain mechanism (during power outage) |
| Target door type | Industrial sectional + Full Vision |
Control
| Feature | Value |
|---|---|
| Compatible control board | GIGA Sedo or I-380 |
Videos
You can find all of our product and installation videos on our YouTube channel.
Visit Our YouTube ChannelOverview
For medium-to-large industrial sectional doors and Full Vision showroom doors, the r-tec SIRIUS 10024 TCE is the standard answer in its segment: a 100 Nm torque class, 380 V three-phase supply, 0.37 kW motor power and 24 cm/sec movement speed. Open and close limit positions are set in software through the electronic limit switch, while the shaft-driven construction couples the motor directly to the door. Should the power fail, the chain mechanism lets the door be operated by hand.
Key specifications (PDF verified)
| Feature | Value |
|---|---|
| Full product name | SIRIUS 10024 TCE |
| Power supply | 380 V three-phase |
| Motor power | 0.37 kW |
| Torque | 100 Nm |
| Movement speed | 24 cm/sec |
| Limit switch | Electronic limit switch |
| Drive | Shaft driven |
| Manual mode | Chain mechanism (during power outage) |
10024 TCE vs 10024 TCE-C vs 14017 TCE
| Model | Torque | Motor power | Speed | Target market |
|---|---|---|---|---|
| 10024 TCE | 100 Nm | 0.37 kW | 24 cm/sec | Standard industrial + Full Vision |
| 10024 TCE-C | 100 Nm | 0.37 kW | 24 cm/sec | Compact variant (narrow space, kit) |
| 14017 TCE | 140 Nm | 0.55 kW | 17 cm/sec | Large-frame, heavy door |
→ 10024 TCE is the primary choice in standard industrial applications. TCE-C for narrow installation space + kit package; 14017 TCE for heavy doors / large-frame.
Manual operation — chain mechanism
In case of a power outage or service requirement, manual operation via chain is a standard feature:
- Pull the chain hanging from the chain mechanism on the motor
- The motor switches to manual mode (automatic mode disengages)
- The door is opened/closed by hand
- When power returns, release the chain mechanism → returns to automatic mode
Target projects
- Industrial sectional door (medium-large frame)
- NORMTOR Full Vision showroom motor (aesthetic priority)
- Automotive factory production line door
- Logistics terminal dock door
- Cold storage facility entrance
- Hangar side door + security entrance
Field discipline
- Three-phase 380 V supply — Clean supply required; if voltage fluctuation > 10%, input regulator recommended
- Limit switch calibration — Full open + full close limit positions programmed via control board
- Cooling air — 10 cm air circulation left around the motor body
- Manual mode test — Chain mechanism’s open/close action is periodically verified
- Periodic maintenance — Once every 6 months limit switch + chain mechanism + reducer oil check
In which sectors is it used?
This product family is preferred in the sectors and application areas below.
- Production facility and factory
- Logistics warehouse
- Cold store
Frequently Asked Questions
Below we've compiled the most common questions and answers regarding this product.
-
How does an electronic limit switch differ from a mechanical one?
A mechanical limit switch breaks the circuit when the door physically contacts a trip lever; it is set by sliding that lever by hand and can drift over time with vibration. An electronic limit switch counts position from the drive shaft, is taught through the board, and needs no mechanical contact, so drift is eliminated. Settings such as an intermediate position or partial opening also become possible this way. In return, the learning procedure must be completed correctly during commissioning; with learning left half done, the door does not recognise its limits.
-
How is the door opened during a power cut?
The motor has a chain mechanism, and during an outage the door is moved by hand with it. This matters on an industrial sectional door for evacuation and emergency egress, because on a shaft-driven arrangement the leaf cannot be pushed by hand. The chain's drop length and accessibility should be planned during installation: a chain that ends up behind racking, pallets or machinery is of no use in an outage. Before switching to manual, confirm the supply really is off, and do not touch the chain while the door is moving.