Documents
All documents open as PDFs in a new tab.
Brochures
2Technical specifications
1Dimensioning forms
1Installation guides
1Declarations and conformity records
2Key technical specifications
The most critical technical parameters of this product.
- REV04 panel thickness 40 mm
- REV04 polyurethane fill density 40 kg/m³
- REV04 panel thermal line 0.604; printed unit unclear, not a complete-door U-value
- REV04 panel acoustic line R'w 26 dB
- REV04 wind requirement EN 12424 class 3; not a measured result for the range
- REV04 water requirement EN 12425 class 2; not a measured result for the range
Show all technical specifications (10)
Test report
| Feature | Value |
|---|---|
| SP 3P00659A specimen | 3040 × 2500 mm; air 2, water 3, wind 5; 2013 specimen only |
Component
| Feature | Value |
|---|---|
| REV04 roller requirement | Polyamide; no guarantee of whole-door silence |
| REV04 outer seal requirement | Rubber flexible to −30 °C; seal only |
Spring
| Feature | Value |
|---|---|
| REV04 spring alternatives | 15,000 standard; 25,000 / 50,000 / 100,000 optional cycles |
Videos
Installation and support guides
These videos demonstrate the model and control board shown. They may provide general reference for other products; use the current technical manual for the relevant model for connections and settings.
PULL1000 garage door motor 5 videos
Motor overview, limits, photocell, remote controls and external receiver connections.
For installations using PULL1000; do not assume the same settings for PULL1200/PULL1200L.
Turkish video archive from the Alkur YouTube channel; titles and topic notes are translated.
System / board reference
An overview of the PULL1000 garage door motor control board and programming features.
- 2:30 Watch on YouTube
An overview of the PULL1000 garage door motor control board and programming features.
- 1:20 Watch on YouTube
A guide to connecting a safety photocell to the PULL1000 garage door motor.
- 2:00 Watch on YouTube
A demonstration of programming garage door opening and closing limits on the PULL1000 motor.
- 0:43 Watch on YouTube
A guide to pairing remote controls and clearing stored remotes on the PULL1000 motor.
- 1:58 Watch on YouTube
A demonstration of connecting an external remote-control receiver to the PULL1000 garage door motor.
Scope of the documents
The published NORMTOR REV04 garage specification is a 2015 product description. It states requirements for panels, rollers, seals, springs and the door; it does not by itself prove that every option remains available in every current size. Match the panel code, dimensions and hardware on the quotation drawing.
Panel figures and door performance
REV04 specifies a 40 mm panel with 40 kg/m³ polyurethane fill. R’w 26 dB is also a panel line. The printed unit beside the panel thermal figure 0.604 is inconsistent; the figure is not presented as a measured U-value for a complete garage door. Windows, wicket doors, perimeter seals and installation alter the configuration, so the current door declaration needs separate review.
The specification sets requirements of EN 12424 wind class 3 and EN 12425 water class 2 for the door. SP report 3P00659A, dated 12 February 2013, records air class 2, water class 3 and wind class 5 for a 3040 × 2500 mm residential-door specimen. That historical result applies only to the tested configuration, not every size or hardware set in today’s range.
Components and options
REV04 specifies polyamide rollers as a noise-reducing material, while its −30 °C line concerns flexibility of the outer rubber seal only. Together they do not guarantee whole-door silence, compliance with a neighbourhood noise limit or durability in every climate. The listed 15,000 standard and 25,000 / 50,000 / 100,000 optional cycles describe torsion springs, not the life of the motor or whole door.
The document offers a plexiglass window and an 840 × 1840 mm wicket door for widths up to 5,000 mm. Manual or motorised use, motor model and safety equipment depend on the proposed opening. The historic garage specification does not establish that one r-tec motor is required or sufficient for every residential garage; verify the exact model manual and project drawing.
In which sectors is it used?
This product family is preferred in the sectors and application areas below.
- House and villa garage
- Residential complex car park
- Small facility service entrance
- Commercial unit storage
Frequently Asked Questions
Below we've compiled the most common questions and answers regarding this product.
-
Do 0.604 and R'w 26 dB apply to the whole door?
No. The REV04 garage specification lists both figures under panels. The printed unit for the thermal line is inconsistent, so 0.604 must not be presented as a confirmed complete-door U-value. Check the declaration for the proposed door size and hardware.
-
Do all garage doors have the same wind and water classes?
No. Wind class 3 and water class 2 in REV04 are manufacturer specification requirements. SP 3P00659A reports air class 2, water class 3 and wind class 5 for one 3040 × 2500 mm specimen tested in 2013. That specimen result is not a claim for the current entire range.
-
What do the polyamide roller and −30 °C statements cover?
REV04 specifies polyamide as roller material and flexibility down to −30 °C for the outer rubber seal only. Neither establishes silent operation, climate durability or an acoustic rating for the complete door.
-
How are motors and options selected?
The garage specification describes manual or motorised use, a plexiglass window and a wicket-door option for stated sizes. Confirm motor, springs, window and wicket-door fit on the proposed door drawing and exact model manual. One motor is not assumed sufficient for every residential garage.