Quick selection
Models 6
Click on a model to view its technical page. Technical documents are provided as PDFs on this site.
Pre-selection tool
Swing gate motor pre-selection
Narrow down the right motor class by leaf length, leaf weight and battery backup needs.
Hinge to leaf tip. For double leaves, use the longer leaf.
Weight of a single leaf. If unknown, enter an approximate value — we confirm it during quotation.
If the gate must operate during a power cut, a 24 V series motor is required.
Pre-selection summary
Entered values
Matching models
Pre-selection result based on your values. Open a product page from the cards or request a quote directly.
No model matches these values. Please check the dimensions or get in touch with us.
- r-tec SW2 (220 V Swing) Recommended
- Power supply
- 230 VAC 50 Hz
- Max. door weight
- 200 kg
A relevant technical value for this model is missing from our data and will be confirmed during quotation.
- r-tec COUPER 24 Recommended
- Power supply
- 230 VAC 50 Hz
- Motor voltage
- 24 VDC
- Speed
- 1.3 / 1.6 cm/s
A relevant technical value for this model is missing from our data and will be confirmed during quotation.
- r-tec LINEAR 400 Recommended
- Power supply
- 230 VAC 50 Hz
- Motor voltage
- 24 VDC
- Speed
- 1.6 / 2.0 cm/s
A relevant technical value for this model is missing from our data and will be confirmed during quotation.
- r-tec PRINCE 400 Recommended
- Power supply
- 230 VAC 50 Hz
- Motor voltage
- 24 VDC
- Speed
- 1.6 / 2.0 cm/s
A relevant technical value for this model is missing from our data and will be confirmed during quotation.
- r-tec JET 24 Recommended
- Power supply
- 230 VAC 50 Hz
- Motor voltage
- 24 VDC
- Speed
- 1.3 / 2.0 cm/s
A relevant technical value for this model is missing from our data and will be confirmed during quotation.
- r-tec PRINCE 600 Recommended
- Power supply
- 230 VAC 50 Hz
- Motor voltage
- 24 VDC
- Max. door weight
- 600 kg
A relevant technical value for this model is missing from our data and will be confirmed during quotation.
This tool is for pre-selection. The final model is determined during quotation, once door weight and site conditions are confirmed.
Documents
All documents open as PDFs in a new tab.
Key technical specifications
The most critical technical parameters of this product.
- Voltage segments 24 V DC / 220 V AC
- Max. leaf length 2 – 4 m (by model)
- Max. door weight 200 – 600 kg (by model)
- Control board (24 V series) G24 (modular board slot)
- Protection class IP44
- Operating temperature -20 – +50 °C
Videos
Installation and support guides
These videos demonstrate the model and control board shown. They may provide general reference for other products; use the current technical manual for the relevant model for connections and settings.
24 V swing gates 8 videos
GATE24/G24A board, motor and limit learning; safety and remote control connections.
Reference for the 24 V motor and GATE24/G24 board shown; not for 220 V motors.
Turkish video archive from the Alkur YouTube channel; titles and topic notes are translated.
System / board reference
An overview of the G24A control board, its connection points and adjustment controls.
- 5:14 Watch on YouTube
An overview of the G24A control board, its connection points and adjustment controls.
- 5:04 Watch on YouTube
A demonstration of connecting a 24 V swing gate motor to the GATE24 controller.
- 2:21 Watch on YouTube
A guide to programming opening and closing limits on a 24 V swing gate motor.
- 1:41 Watch on YouTube
A technical demonstration of connecting a safety photocell to the G24 control board.
- 0:24 Watch on YouTube
A short guide to connecting a warning flasher to the G24 control board.
- 1:01 Watch on YouTube
An example of connecting a vehicle-detection loop detector to the G24 control board.
- 0:48 Watch on YouTube
A demonstration of pairing a Fix Code remote control and clearing stored remote-control entries.
- 1:07 Watch on YouTube
A demonstration of connecting an external remote-control receiver to the G24 control board.
Overview
Unlike rail gates, swing garden gates do not slide sideways; the leaf opens by rotating 90°–110° around the hinge axis. r-tec swing gate motors automate these rotating gates in single- or double-leaf form, and the portfolio is offered in 6 models according to arm mechanism and speed class.
Model comparison
| Model | Voltage | Arm mechanism | Motor power | Max. leaf | Max. weight | Typical use |
|---|---|---|---|---|---|---|
| COUPER 24 | 24 V DC | Articulated (classic) | 85 W | 2 m | 250 kg | Residential + villa, standard |
| JET 24 | 24 V DC | Fast articulated | 120 W | 3 m | 600 kg | Heavy door + frequent use |
| PRINCE 24 | 24 V DC | Telescopic | 120 W | 3 m | 400 kg | Wide leaf, deep strut |
| PRINCE 600 | 24 V DC | Telescopic | 120 W | 4 m | 600 kg | Wide leaf + heavy door |
| LINEAR 400 | 24 V DC | Piston (linear) | 120 W | 3 m | 400 kg | Narrow wall clearance alternative |
| SW2 (220 V) | 220 V AC | Articulated | — | 2 m | 200 kg | Single-phase installation, simple |
Arm mechanism differences
Articulated (classic) arm — COUPER, SW2: Two-piece jointed arm. Classic design, tested in wide field application. Typical for ordinary villa and residential gardens.
Fast articulated — JET: Same mechanism + stronger motor + different gear ratio. Leaf opening time is ~30% shorter compared to standard COUPER. For high-use premium villa entrances.
Telescopic — PRINCE: Single-piece extending arm. Operates on gates with wide leaves (up to 4 m) and deep strut distances. Requires liquid grease periodic maintenance.
Single-leaf vs double-leaf installation
- Single leaf — 1 motor + G24 board standard. Typical up to 2 m leaf.
- Double leaf — 2 motors + G24-MTS module (2nd motor driver board add-on module). Sync limit setting is mandatory; the two leaves move at the same time or one closes first when closing (for overlap applications).
Opening angles (90° / 100° / 110°)
The angle the leaf reaches when fully open depends on the arm mechanism geometry:
- 90° — Standard full opening; perpendicular into the garden.
- 100° — Wide manoeuvre area; extra space for long vehicle (minivan, SUV) transit.
- 110° — Maximum opening; applications where the obstacle is temporarily moved to the side.
In site installation, the A-E distances between the door hinge and the motor shaft axis are calculated according to the diagram in the PDF.
G24 universal control board
The 24 V DC swing motors (COUPER, JET, PRINCE) operate on a single board:
- 230 VAC input → 24 VDC output.
- 2 motor terminals (2nd motor with G24-MTS module).
- 2 photocell channels (opening + closing direction).
- 433 MHz rolling-code receiver slot (RF433-S module).
- Battery charger board compatibility (operates during power outages).
- Flasher, traffic light, electric lock terminals.
- Motor type selection with BT2: swing = D4 LED steady on.
Target projects
- Residential garden and villa entrance gates (single or double leaf)
- Premium villa complex vehicle + pedestrian combined entrance
- Eco-house + solar-powered systems (24 V natural compatibility)
- Historical residence + restoration applications (aesthetic priority)
- Facility additional/side gate entrances (artistic design emphasis)
Field discipline
- Power trimpot calibration — Set the motor power adjustment trimpot according to your door’s weight. High power on a light door strains the connection set.
- Hinge quality — Sprung or well-bearing hinges reduce load fatigue on the motor.
- Strut distance — The distance (A dimension) from the motor mounting location to the leaf hinge must be according to the installation table in the PDF.
- Double-leaf synchronisation — The sync limit setting must follow the order in the document; otherwise the leaves may collide.
- Periodic maintenance — Every 12 months 1 hinge lubrication + arm connection tightening + reducer check.
Warning
Caution! Set the motor power adjustment trimpot according to your door’s weight.
In which sectors is it used?
This product family is preferred in the sectors and application areas below.
- Villa and detached house garden
- Residential complex gate
- Corporate campus entrance
- Small production facility yard
Frequently Asked Questions
Below we've compiled the most common questions and answers regarding this product.
-
Backing off against excessive load is triggered too late on a garden gate
Possible causes: force (force/torque) trimpot setting at a high value, leaf weight has increased (panel or casting-like accessory added later), motor mechanical friction has decreased (adjustment needed after lubrication), momentum effect because the speed setting is high. Initial intervention: apply the force learning procedure in the model guide; if there is a change in leaf weight, motor capacity should be re-evaluated. The EN 12453 standard emphasizes that force adjustment is critical for personal safety; bring it to the minimum required value.
-
Garden motor leaf is not stopping at the end-stop
Possible causes: mechanical stop position drift, end-stop limit switch trigger arm bent, control board took an incorrect record in learning mode, gear coupling slippage. Initial intervention: visually check that the mechanical stop is in place, check whether the limit switch arm is in the correct position, run the learning mode from the control board again (with the step in the guide). Instead of changing parameters by on-site observation, the first intervention is to repeat the motor learning process in the order in the guide.