What Do Insulation Values Mean on a Sectional Door? U and R'w Guide

How should U and R'w be read for panels and complete doors? A guide to the ambiguous thermal unit and acoustic reference in the 40 mm panel document.

What Do Insulation Values Mean on a Sectional Door? U and R'w Guide

Published:

Publisher: Alkur Kapı Sistemleri A.Ş.

By:

Two abbreviations keep appearing in technical specifications: U and R’w. Both attach a measurable value to the word “insulated”, but a panel value and the performance of a complete installed door are not the same thing. In this article we explain how to read these numbers using the published technical values of the NORMTOR industrial sectional door.

NORMTOR industrial sectional door — facade application with 40 mm sandwich panels.

Read the documented value step by step

  1. Define the requirement: temperature separation, sound expectation or both.
  2. Check whether the document describes a panel, a specific test door or the complete door offered.
  3. Record model, size, revision and the unit exactly as printed together.
  4. Check windows, wicket doors, perimeter seals and joints against the quotation scope.
  5. Do not turn an incomplete or ambiguous unit into a definite value; request current scope confirmation through the dealer.

U-value: How fast does heat escape?

The U-value (thermal transmittance) expresses the heat flow through one square metre of a building element for every 1 K temperature difference between its two sides. The lower the value, the lower the heat transfer. The REV04 English panel line prints 0.604 k (W/m²). The unit is ambiguous; verify the current manufacturer declaration before using this as a definite panel or complete-door U-value.

That does not mean the complete door returns the same figure at every size. Overall installed performance is affected by the opening dimensions, panel joints, windows or a wicket door, perimeter seals and installation details. In cold-chain and climate-separation applications, the panel value and project configuration therefore have to be assessed together.

R’w value: How much sound stays inside?

R’w is a single-number indicator used to express apparent sound-reduction performance in the field. Alkur’s technical documentation publishes R’w = 26 dB for the 40 mm panel. The figure supports comparison, but the facade, junctions, flanking paths and installation conditions mean it cannot by itself guarantee the sound level in an adjacent space or the environmental-noise outcome.

The structure behind the number

These are panel values published in Alkur’s technical documentation. The density of the polyurethane core, the bond of the steel skins and the tongue-and-groove edge geometry all work together. Seals are part of the equation too — if threshold and frame tightness degrades, the panel figure no longer describes the complete installed door.

How much does it matter in which project?

On an internal partition door the U-value can be secondary; on an external dispatch facade or a cold-store entrance it sits at the centre of the decision. A specification should not copy the panel value alone: it should also state the door dimensions, window and wicket-door options, perimeter tightness and installation detail.

Evidence record for comparison

Field to record from the documentWhy it is needed
Model and revisionPrevents mixing products or editions.
Panel / sample / complete-door scopeIdentifies the construction covered by the result.
Value and original unitPrevents deriving a definite U-value from a missing unit.
Size and accessory configurationShows whether quotation and evidence concern the same door.
Document type and pending confirmationSeparates a specification clause from tested performance.

Keep “required performance”, “documented scope” and “pending information” separate in the completed file. Site measurement, installation and building acoustic/thermal calculations belong to the relevant project teams; Alkur does not conduct site surveys. The ambiguous REV04 heat-transfer line is not entered as a verified whole-door U-value in a bid comparison.

Sources and evidence

Original sources for this publication and the specific information each link supports.

  1. BS EN 12428:2013, thermal transmittance for industrial doors (opens in a new tab)
    Publisher:
    British Standards Institution
    URL
    knowledge.bsigroup.com
    Published:
    Last verified:

    Claim supported: Defines the standard and scope for calculating thermal transmittance of industrial, commercial and garage doors.

  2. ISO 10140-2:2021, laboratory measurement of airborne sound insulation (opens in a new tab)
    Publisher:
    International Organization for Standardization
    URL
    iso.org
    Last verified:

    Claim supported: Defines the laboratory measurement method for airborne sound insulation of building elements.

  3. ISO 717-1:2020, rating of airborne sound insulation (opens in a new tab)
    Publisher:
    International Organization for Standardization
    URL
    iso.org
    Last verified:

    Claim supported: Explains single-number rating of measured airborne sound insulation for building elements including doors.

  4. NORMTOR Industrial Sectional Door Technical Specification (opens in a new tab) PDF language: TR / EN
    Publisher:
    Alkur Kapı Sistemleri
    URL
    alkur.com.tr
    Last verified:

    Claim supported: Defines the 40 mm panel and 40 kg/m³ polyurethane infill, its acoustic reference, and the ambiguous printed unit of 0.604 in the REV04 English thermal line.

You can open the related FAQ question for a short answer.

Share this publication

Publications home

Contact

You're close to a journey full of innovation and inspiration

Reach our team for product selection, technical specifications or a price quote.

Alkur Kapı Sistemleri operates exclusively B2B. Sales and services are handled through dealers, distributors and business partners; we do not sell products or provide services or technical support directly to end users.

Our B2B sales and service model